Title: Leica TS0x series
Topic ID: 858 Link to this page
Category: SurvCE|PC / SurvCE / Quick Start Guides / Leica Instruments
Modified: 2014-06-18 Created: 2014-06-18
This is in regards to the Leica Geosystems Flexline instrument

This includes the models below from Leica:
TS02, TS06, and TS09

Set it to the "CR_LF" option {don't use just "CR"}

***On the TS02 to access the settings in the instrument:***
    1) From the Main Menu select "Settings"
    2) From the Settings Menu select "Comm"
    3) For using a 9pin instrument cable change the Port to "RS232"
--> Please Note: to use Bluetooth set Port to "Bluetooth" and use a pin of "0000"
    4) Set the defaults as shown below:
          1. Baud --> 19200
          2. Databits --> 8
          3. Parity --> None
	  4. Endmrk --> CR/LF {if its on CR hit Arrow Right ->}
          5. Stopbits --> 1
    5) After filling out all the settings tap F4 for "OK"
    6) hit ESC to return to the Measure screen

***In SurvCE 2.61 or higher:***
    1) Go into Equip / Total Station
    2) Set the Manufacturer to "Leica TPS Series (Direct)"
    3) Set the Model to "TS0x"
    4) Tap the Comms tab and set it up for:
      Type: Cable
      Port: Com1
      Baud: 19200 / Data Bits: 8 / Parity: None
    5) Tap the "Settings" tab and select your FS Target and BS Target prism options
    6) Tap the Green Check in the upper right to save your Changes