Leica TPS 1000 Series:
· TC1100, TC1100L, TC1500, TC1500L, TC1700, TC1700L, TC1800, TC1800L
· TCM1100, TCM1100L, TCM1800, TCM1800L
· TCA1100, TCA1100L, TCA1800, TCA1800L
Leica TPS TCA1800 (Remote)
Leica - Communication Settings (19200,8,None,1)
***On the Leica 1000 instrument***
1. Turn on the instrument
2. Level the instrument
3. Select F3 - Soft Key “CONF”
4. Select menu item 4 - “GeoCOM communication param.”
5. Highlight “Baud rate”
6. Select F6 - Soft Key “LIST”
7. Highlight “19200”
8. Press the enter key “↵” to accept
9. Verify that the “Protocol” is “GeoCOM”
10. Highlight “Parity”
11. Select F6 - Soft Key “LIST”
12. Highlight “NO”
13. Press the enter key “↵” to accept
14. Verify the “Terminator” is “CR LF”
15. Highlight “Data bits”
16. Select F6 - Soft Key “LIST”
17. Highlight “8”
18. Press the enter key “↵” to accept
19. Verify “Stop bit” is 1
20. Select the “CONT” button to set parameters
21. Select F1 - Soft Key “EXTRA”
22. Select menu item 1 - “On-Line mode
23. Select F5 - Soft Key “YES”
***In SurvCE 2.58 or higher***
1) Equip / Total Station
2) Set the Manufacturer to "Leica Robotic Total Station"
3) Set the Model to "TPS 1000"
4) Tap the Comms tab and set it to Type: Radio and Radio: "Cable or Generic"
5) Com1 / Baud: 19200 / Data Bits: 8 / Parity: None
6) Tap the "Settings" tab and select your FS Target and BS Target prism options
7) Tap the Green Check in the upper right to save your Changes