Title: Leica 1100 Series - Direct
Created: 2013-06-05Last modified: 2013-06-05
Leica TPS 1100 Series:
·  TC1101, TC1102, TC1103, TC1105
·  TCR1101, TCR1102, TCR1103, TCR1105
·  TCM1101, TCM1102, TCM1103, TCM1105
·  TCRM1101, TCRM1102, TCRM1103, TCRM1105
·  TCA1101, TCA1102, TCA1103, TCA1105
·  TCRA1101, TCRA1102, TCRA1103, TCRA1105


Leica TPS TCRA1101, 1103, 1105 (Direct) 
    Leica - Communication Settings (19200,8,None,1)

***On the Leica 1100 instrument:***
  1. Turn on the instrument 
  2. Level the instrument 
  3. From the main menu select menu item 5 - “Configuration” 
  4. Select menu item 2 - “Communication mode” 
  5. Select menu item 1 - “GSI parameters” 
  6. Highlight “Baudrate” and press the enter key “↵” 
  7. Highlight “19200” and press the enter key “↵” to accept 
  8. Verify that the “Protocol” is “GSI” 
  9. Highlight “Parity” and press the enter key “↵” 
  10. Highlight “None” and press the enter key “↵” to accept 
  11. Verify the “Terminator” is “CR LF” 
  12. Highlight “Data Bits” and press the enter key “↵” 
  13. Highlight “8” and press the enter key “↵” to accept 
  14. Verify “Stop Bit” is 1 
  15. Select F1 - Soft key “CONT” to set parameters 
  16. Select F1 - Soft key “BACK” 
  17. Select F1 - Soft key “BACK” 
  18. Select F6 - Soft Key “MEAS”


***In SurvCE 2.58 or higher***
    1) Equip / Total Station
    2) Set the Manufacturer to "Leica TPS Series (Direct)"
    3) Set the Model to "TPS 1100"
    4) Tap the Comms tab and set it up for:
      Type: Cable
      Port: Com1
      Baud: 19200 / Data Bits: 8 / Parity: None
    5) Tap the "Settings" tab and select your FS Target and BS Target prism options
    6) Tap the Green Check in the upper right to save your Changes