Carlson Software Knowledge Base

Carlson Software Knowledge Base
Downloads KB Home Tech. Support
Search by Keyword
Title: Leica TC805L
Topic ID: 802 Link to this page
Category: SurvCE|PC / SurvCE / Quick Start Guides / Leica Instruments
Modified: 2024-04-22 Created: 2013-05-29

The TPS100 Series were introduced in 1996/97. These Total Stations were the first series supporting an enhanced set of GSI interfacing commands.

This includes the models below from Leica:

  • TC403L, TC600, TC800 (Firmware Version 2.13 and higher)
  • TC605, TC605L, TC805, TC805L, TC905, TC905L
  • T1610

On the TC805L to access the settings in the instrument:

  1. Hold the Menu button for 2 seconds
  2. tap "4." for "Rec Data"
  3. Set the defaults as shown below:
    • DATout → RS232 {If its on MEM hit Arrow Right ->}
    • Format → 16
    • RS232 → MASK1
    • Baud → 1200
    • Parity → Even
    • Endmrk → CR/LF {if its on CR hit Arrow Right ->}
  4. After filling out all the settings hit ENTR to save the changes
  5. hit ESC to return to the Measure screen
Leica TC805L

In SurvCE 2.62 or higher:

  1. Go into Equip / Total Station
  2. Set the Manufacturer to "Leica TPS Series (Direct)"
  3. Set the Model to "TPS 100 Series"
  4. Tap the Comms tab and set it up for:
    • Type: Cable
    • Port: Com1
    • Baud: 1200 / Data Bits: 7 / Parity: Even
  5. Tap the "Settings" tab and select your FS Target and BS Target prism options
  6. Tap the Green Check in the upper right to save your Changes

Links:

Attachments:

Leica TC805L user manual.pdf
Leica_TC805L.jpg

Keywords: